Dameng Testing

Home > News

EMC Test Failures: Common Fixes and Troubleshooting

Failing an EMC test on the first attempt is one of the most common experiences for R&D and QC teams — don't panic, most issues have well-established fixes.

Radiated Emissions Exceeding Limits

This is the most common failure, usually related to PCB layout, clock circuits, or grounding design. Common fixes include:

  • Optimizing PCB traces, shortening high-frequency signal line lengths
  • Adding shielding enclosures or shielding materials
  • Adjusting grounding to ensure sufficiently low ground impedance
  • Adding ferrite beads on critical signal lines

Conducted Emissions Exceeding Limits

This most often shows up at the power input. Common fixes include:

  • Adding an EMI filter
  • Optimizing power module layout to reduce switching noise coupling
  • Checking whether cable shielding is properly grounded

Immunity Test Failures

The product exhibits abnormal behavior (crashing, resetting) under external electromagnetic interference. Common fixes include:

  • Adding decoupling capacitors to critical circuits
  • Optimizing the software watchdog mechanism for automatic recovery after abnormal events
  • Adding common-mode chokes on signal lines

Recommended Remediation Process

  1. Get the detailed failure data (not just "failed" — look at the specific frequency band and how much it exceeds the limit)
  2. Have your engineering team assess whether a hardware or software-level fix is more cost-effective
  3. Validate the fix on a small batch of samples
  4. Retest to confirm

Throughout testing, we provide detailed raw data and engineering recommendations — not just a pass/fail conclusion — so your team can pinpoint issues more precisely and reduce the number of retest cycles.